VB-SYJ620 petroleum coke industrial analyzer

Picture Name
It is applicable to the following fields: ① calculation of moisture, ash and fixed carbon and calorific value of solid/hazardous waste, coal, coke and solid biomass fuel; ② analysis of carbon content of fly ash and ash;

Classification: Industrial Analysis Series

Email: vbjd2010@126.com

VB-SYJ620 petroleum coke industrial analyzer
+
  • VB-SYJ620 petroleum coke industrial analyzer

Application areas

It is applicable to the following fields: ① calculation of moisture, ash and fixed carbon and calorific value of solid/hazardous waste, coal, coke and solid biomass fuel; ② analysis of carbon content of fly ash and ash;

 

regular technical parameters

1) Sample weight: 0.8-5.1g (custom setting), particle size: ≤ 0.2mm, balance accuracy: 0.0001g

2) furnace temperature range: room temperature ~ 1000 ℃ (arbitrarily set constant temperature point); Temperature control accuracy: 1 ℃, temperature control point: moisture: 105~300 ℃ (arbitrarily set constant temperature point), ash: 850±5 ℃ (arbitrarily set constant temperature point), volatile matter: 900±5 ℃ (arbitrarily set constant temperature point)

3) Test time:<180Min/23 samples (constant temperature time can be set arbitrarily according to sample type)

4) voltage: 220V 50Hz, maximum power:<5Kw

5) Accuracy: 0.15, reproducibility: 0.20, in line with YS/T 581.2-2006 national standard

6) water ash part size mm:555*580*525 volatile part size mm:660*450*820

 

Performance requirements

1. The furnace wire is not exposed, corrosion-resistant design, and the service life is more than 3 years.

2. Automatic switch cover, automatic weighing, one batch lofting can analyze the water content and ash content of the sample.

3, according to user needs, can be configured to achieve a variety of thermal analysis indicators, such as moisture, ash, fly ash/ash carbon content analysis, etc.

4. The water ash equipment adopts the electric push rod mode to automatically open and close the furnace door, and does not need to use air compressor or air source to avoid the damage to the furnace body caused by sudden cooling and sudden heating.

5. The real-time display function of weighing is convenient for users to weigh accurately and effectively.

6. The balance is independently located in the constant temperature zone, with ultra-fast stabilization device, working at a high temperature above 800 ℃ for more than 3 hours at a constant temperature, and the temperature rise in the constant temperature zone is not higher than 5 ℃. The balance is more stable and the experimental data is more reliable.

7. The volatile matter equipment adopts double guide rail translation technology to ensure the docking between every two samples and the furnace. Using standard crucible, no manual participation, no need to pass nitrogen.

8. Automatically generate reports. (Users can design reports according to their own needs). Can be online direct reporting data.

 

Product Message

If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!

Submit Message